Control the infusion of infusion or infusion flow rate, to ensure that the drug can be uniform, accurate and safe access to the patient's body to play a role in the instrument, commonly used in the need to strictly control the amount of infusion and the amount of the situation. Small size, easy to operate, save manpower Dose accurate, trace, sustained, timing control dosage, equipped with a controller, the amount of drip per hour can be controlled between 0.1 ~ 2000ml To avoid drug fluctuations due to fluctuations in the size of the side effects There are batteries in the pump, AC interruption to ensure continued medication On the rescue of critical cases, reduce the labor intensity of nursing work has obvious advantages
Price:¥2500/set;
Payment:T/T,Paypal,West union,Credit card
Dimensions (mm): 140 (L) x 160 (W) x 220 (H)
Weight: 2.15kg
Power supply: AC power: AC 100 ~ 240V, 50 / 60Hz (± 1 Hz)
Built-in battery: DC 12V 2800mAh Model: Ni-MH, recharge able
Continuous use of time: 6 hours or more
Power consumption: ≤ 18VA
Infusion flow rate and resolution: Flow rate setting range: 0.1ml / h ~ 1200ml / h (6 ~ 150d / min)
The minimum resolution is: 0.1ml / h (1d / min)
Infusion total and resolution: the total setting range: 0.1ml ~ 9999.9ml
The minimum resolution is: 0.1ml
Infusion mode: flow rate mode ml / h (convertible weight mode), drop mode d / min, time mode hr: min
Infusion Accuracy: ± 5% of capacity mode (± 10% below 1ml / h), drip mode ± 2d
Blocking alarm threshold: high: 110kPa ± 20kPa (825mmHg ± 150mmH g)
In: 80kPa ± 30kPa (600mmHg ± 225mmHg)
Low: 60kPa ± 20kPa (450mmHg ± 150mmHg)
Alarm volume: third gear adjustable (points high, medium and low), the alarm sound according to the latest national standard YY0709-2009 design, suitable for different hearing groups, to prevent the sound was submerged, the alarm sound more secure
Use of the environment: Ambient temperature: 5 ℃ ~ 43 ℃
Relative humidity: ≤90% RH (no condensation)
Atmospheric pressure: 860hPa ~ 1060hPa
Storage environment: Ambient temperature: -20 ℃ ~ +55 ℃
Relative humidity: ≤ 95% RH (no condensation)
Atmospheric pressure: 860hPa ~ 1060hPa
Waterproof rating: IPX1
Electric shock protection: Class I BF type
Calibration unit: infusion accuracy calibration unit ml, pressure calibration unit kPa